Power Generators

NEP manufactures 50Hz and 60Hz industrial, marine and military diesel power generators for all international ratings and emission guidelines with extensive ranges of different power outputs from 5KVA to 3500KVA. Our premium branded industrial, marine and military generating sets 5KVA – 3500KVA are available from stock or can be tailored according to your needs and specifications as well as be supported via our range of maintenance, service and remote monitoring programs. Our generators are equipped with global leading engines and alternators, such as Perkins, MTU, Cummins, Volvo, Lister Petter and Deutz, Stamford, Leroy Somer and Mecc alte. Also, key and auto start panels and breaker boxes, up to 2000 KVA available from stock.

NEP’s gensets designed and built in UK via certified British engineers from the top branded engines and alternators as well as high quality base frames and control panels to deliver excellent power performance. The gensets are either EU emission compliant and non-compliant. Also, NEP offer a comprehensive range of mechanical and electrical options including automatic load transfer panels. These incorporate either 3-pole or 4-pole electrically and mechanically interlocked contactors or circuit breakers (from 25 amps to 6300 amps) that are CE Compliant.

NEP are pleased also to satisfy specific needs and demands, such as supplying gensets in excess of 3000KVA, alternative engine and alternator combinations, multi-set installations, HV generation, remote cooling, bespoke control panels using alternative generator set controllers or with PLC control, etc.

 



Model4

E-mail Print PDF
Tempest Specification
Model Perkins Engine (Tropical radiator) Stamford Alternator 50 Hz Volts 50 Hz 3 Phase 60 Hz 3 Phase
KVA AMPS KVA KVA AMPS KVA
PRP PRP ESP PRP PRP 220 V ESP
PS745 4006-23TAG2A HCI634G 380-415 745 1133 815 758 1992 833
PS800 4006-23TAG3A HCI634G 380-415 800 1217 850 845 2220 930
PS800# 4006-23TAG3A HCI634H 380-415 - - 900 - - -
PS910 4008TAG1A HCI634H 380-415 910 1384 1000 875 2299 965
PS1000 4008TAG2A HCI634J 380-415 1000 1521 1100 995 2614 1095
PS1000 4008TAG2A HCI634J 400 1025 1481 1110 - - -
PS1025 4008TAG2A HCI634K 380-415 1025 1559 1125 - - -
PS1250 4012-46TWG2A PI734B 380 1250 1901 1375 1245 3271 1370
PS1250# 4012-46TWG2A PI734A 400 & 415 1250 1806 1350 - - -
PS1360 4012-46TWG3A PI734B 380 1360 2069 1455 1360 3573 1495
PS1360 4012-46TWG3A PI734B 400 & 415 1360 1965 1500 - - -
PS1360# 4012-46TAG1A PI734B 380 1360 2069 1455 1360 3573 1495
PS1360# 4012-46TAG1A PI734B 400 & 415 1360 1965 1500 - - -
PS1500 4012-46TAG2A PI734C 380 1500 2282 1615 1500 3941 1605
PS1500 4012-46TAG2A PI734C 400 & 415 1500 2168 1650 - - -
PS1700 4012-46TAG3A PI734E 380-415 1700 2586 1870 1710 4493 1881
PS1840 4016TAG1A PI734E 380 1840 2799 1975 - - -
PS1840 4016TAG1A PI734E 400 & 415 1840 2659 2024 - - -
PS2000 4016TAG2A PI734F 380 2000 3042 2165 - - -
PS2000 4016TAG2A PI734F 400 & 415 2000 2890 2200 - - -
PS1850 4016-61TRG1 PI734E 380 1845 2807 1975 To be Advised
PS1850 4016-61TRG1 PI734E 400 & 415 1860 2688 2018
PS2000# 4016-61TRG2 PI734F 380 2000 3042 2165
PS2000# 4016-61TRG2 PI734F 400 & 415 2000 2890 2200
PS2250 4016-61TRG3 PI734G 380 2135 3248 2290
PS2250 4016-61TRG3 PI734G 400 & 415 2200 3179 2360
PS2250# 4016-61TRG3 LV804R 380-415 2250 3251 2475

PRP = Prime Power

ESP = Emergency Standby Power, alternator rating based on 27 degrees C ambient

All ratings are in accordance with ISO8528-1 and are at 0.8 lagging power factor

 

Model3

E-mail Print PDF
Tempest Specification
Model Perkins Engine 50 Hz Alternator 50 Hz 3 Phase 60 Hz 3 Phase
KVA AMPS KVA KVA AMPS KVA
PRP PRP 380 V ESP PRP PRP 220 V ESP
PS300 2206A-E13TAG2 Stamford HCI444D 300 456 330 360 946 395
PS350 2206A-E13TAG2 HCI444E 350 532 380 (1) 400 1051 440
PS350# 2206A-E13TAG2 HCI444F - - 400 - - -
PS400 2206A-E13TAG3 HCI444F 400 608 425(2) - - -
- 2206A-E13TAG6 - - - - 440 1156 484
PS450 2506A-E15TAG1 HCI544C 450 685 495 510 1340 560
PS500 2506A-E15TAG2 HCI544D 500 761 550 - - -
PS500# 2506A-E15TAG2 (400 V) HCI544C 500 723 520 - - -
- 2506A-E15TAG4 - - - - 580 1524 640
PS600 2806A-E18TAG1A HCI544E 600 913 660 635 1668 698
PS650 2806A-E18TAG2 HCI544F 650 989 710 - - -
- 2806A-E18TAG3 - - - - 690 1813 760
PM300 2206A-E13TAG2 (400 & 415 V) Mecc-Alte ECO38-2LN 300 456 330 POA
PM350 2206A-E13TAG2 ECO38-3LN 350 532 370
PM350# 2206A-E13TAG2 ECO40-1S - - 400
PM400 2206A-E13TAG3 ECO40-1S 400 608 438
PM450 2506A-E15TAG1 ECO40-2S 450 685 491
PM500 2506A-E15TAG2 ECO40-3S 500 761 546
PM600 2806A-E18TAG1A ECO40-1.5L 600 913 660
PM650 2806A-E18TAG2 ECO402-L 650 989 710

PRP = Prime Power                         
ESP = Emergency Standby Power, alternator rating based on 27 degrees C ambient

All ratings are in accordance with ISO8528-1 and are at 0.8 lagging power factor

 

Model2

E-mail Print PDF
Tempest Specification
Model Perkins    Engine Stamford Alternator 50 Hz 50 Hz 3 Phase 60 Hz 3 Phase
KVA AMPS KVA KVA AMPS KVA
PRP PRP 380 V ESP PRP PRP 220 V ESP
PS8 403D-11G P044D 7.5 11 8.3 10 26 11
PS12 403D-15G P044F 12 18 13.2 14.7 39 16.2
PS17.5 404D-22G P044H 17.5 27 19.3 23 60 25
PS20 404D-22G P144D/BCI184E 20 30 22 - - -
PS25 1103A-33G P144E 25 38 27.5 29 76 32
PS27.5 1103A-33G P144F 27.5 42 30 35 92 38
PS30 1103A-33G P144G 30 46 33 - - -
PS40 1103A-33TG1 P144J 40 61 44.0 - - -
PS42.5 1103A-33TG1 P144K 42.5 65 46.8 52.5 138 56
PS45 1103A-33TG1 UCI224D 45 68 49.5 - - -
PS60 1103A-33TG2 UCI224E 60 91 63 66 173 72.5
PS65 1104A-44TG1 UCI224F 65 99 71.5 75 197 82.5
PS80# 1104A-44TG2 UCI224G 80 122 88 92 242 101
PS80 1104C-44TAG1 UCI224G 80 122 88 90 236 99
PS85 1006TG1A UCI224G 85 129 90.8 109 286 119
PS93 1006TG1A UCI274C 93 141 103 - - -
PS100 1104C-44TAG2 UCI274C 100 152 110 113 297 125
PS100# 1006TG2A UCI274C 100 152 110 121 318 132
PS103# 1006TG2A UCI274D 103 157 113 - - -
PS140 1006TAG UCI274E 138 210 150 152 399 167
PS150 1006TAG2 UCI274F 150 228 165 - - -
PS180 1106C-E66TAG4 UCI274G 180 274 198 200 525 220
PS200 1306C-E87TAG3 UCI274H 200 304 220 234 615 256
PS225 1306C-E87TAG4 UCD274J 225 342 248 245 644 265
PS250 1306C-E87TAG6 UCD274K 250 380 275 - - -
50 Hz 1 Phase 60 Hz 1 Phase
PRP 220 V PRP 220 V
PS8/1P 403D-11G P044F 7.5 34 8.3 9.5 43 10.5
PS12/1P 403D-15G P144D/BCI184E 11.7 53 13 14 64 15.4
PS18/1P 404D-22G P144G 18 82 19.8 21.3 97 23.4
PS25/1P 1103A-33G P144K 25 114 27.5 27 123 30
PS40/1P 1103A-33TG1 UCI224E 40 182 - 49 223 -

PRP = Prime Power
ESP = Emergency Standby Power, alternator rating based on 27 degrees C ambient                        
All ratings are in accordance with ISO8528-1 and are at 0.8 lagging power factor BCI184E is subject to stock remaining

 

Model1

E-mail Print PDF
Model Perkins
Engine
Mecc - Alte Alternator 50 Hz 50 Hz 3 Phase 60 Hz 3 Phase
KVA AMPS KVA KVA AMPS KVA
PRP PRP 380 V ESP PRP PRP 220 V ESP
PM9 403D-11G ECO3-1LN/4 9 14 10 11 29 12.1
PM13 403D-15G ECO3-2LN/4 13 20 14.3 15.5 41 17
PM20 404D-22G ECO28-1LN/4 20 30 21.5 23 60 25
PM25 1103A-33G ECO28-2LN/4 25 38 26.5 27.5 72 29.1
PM30 1103A-33G (380 V & 400 V) ECO28-VL/4 30 (1) 46 32 36 95 38
PM30# 1103A-33G (415 V) ECO32-3S/4 30 42 33 - - -
PM42.5 1103A-33TG1 ECO32-3S/4 42.5 65 46 56 147 61
PM45 1103A-33TG1 ECO32-1L/4 45 68 49.5 - - -
PM60 1103A-33TG2 ECO32-2L/4 60 91 66 68 179 75
PM65 1104A-44TG1 ECO32-3L/4 65 99 71.5 80 210 88
PM80# 1104A-44TG2 ECP34-1S/4 80 122 88 95 250 105
PM80 1104C-44TAG1 ECP34-1S/4 80 122 88 93 244 102
PM85 1006TG1A ECP34-1S/4 85 129 93.5 113 297 124
PM95 1006TG1A ECP34-2S/4 95 145 104.5 - - -
PM100 1104C-44TAG2 ECP34-2S/4 100 152 110 117 307 128
PM105# 1006TG2A ECP34-2S/4 105 160 115 125 328 137
PM140 1006TAG ECP34-2L/4 140 213 154 159 418 175
PM150 1006TAG2 ECP34-2L/4 150 228 164 - - -
PM180 1106C-E66TAG4 ECO38-1SN 180 274 196 200 525 220
PM200 1306C-E87TAG3 ECO38-2SN 200 304 220 235 617 258
PM225 1306C-E87TAG4 ECO38-3SN 225 342 250 250 657 275
PM250 1306C-E87TAG6 ECO38-1LN 250 380 275 - - -
50 Hz 1 Phase 60 Hz 1 Phase
PRP 220 V PRP 220 V
PM8/1P 403D-11G ECO3-2LN/4 8 36 - 10 45 -
PM12/1P 403D-15G ECO28-1LN/4 11.5 52 - 12.5 57 -
PM18/1P 404D-22G ECO28-VL/4 17 77 - 22 100 -
PM24/1P 1103A-33G ECO32-3S/4 24 109 - - - -
PM28/1P 1103A-33G ECO32-1L/4 28 127 - 31 141 -
PM40/1P 1103A-33TG1 ECO32-3L/4 40 182 - 50 227 -
 

News Letter